Thursday, November 19, 2015
Print Current Session:
|
|
Thursday
SESSION 48:
ADVANCES IN BRANCHED AND FENESTRATED EVAR (F/BEVAR) AND PARALLEL GRAFTS FOR LESIONS NEAR TO OR IN THE VISCERAL AORTA
Moderators:Timothy A.M. Chuter, DM / Frank J. Veith, MD
|
|
SESSION 48 SCHEDULE | |
7:58 AM - 8:03 AM | How Durable Are F/B Endografts For Various Aortic Lesions Including TAAAs |
Presenter(s):Tara M. Mastracci, MD | |
View Slides in PDF | |
8:04 AM - 8:09 AM | How Durable Are Parallel Grafts (Chimney And Periscope Grafts) For Various Aortic Lesions Including TAAAs |
Presenter(s):Mario L. Lachat, MD | |
View Slides in PDF | |
8:10 AM - 8:15 AM | Parallel Grafts (Chimneys, Etc.) Do Work As Proven By The PERICLES Registry: Midterm Results With A Variety Of Devices |
Presenter(s):Konstantinos P. Donas, MD / Jason T. Lee, MD | |
View Slides in PDF | |
8:16 AM - 8:21 AM | Parallel Grafts Are Valuable Even If F/BEVAR Is Available |
Presenter(s):Frank J. Criado, MD, FACS, FSVM | |
View Slides in PDF | |
8:22 AM - 8:27 AM | Status Of Sandwich Grafts For Aneurysms Involving The Visceral Segment: What Are The Midterm Results – Single Center And Multicenter |
Presenter(s):Armando C. Lobato, MD, PhD | |
View Slides in PDF | |
8:28 AM - 8:33 AM | Sandwich (Parallel) Grafts Work For TAAAs: How Much Oversizing Of The Main Endograft And Overlap Of The Branch Grafts Are Required |
Presenter(s):Ralf R. Kolvenbach, MD | |
View Slides in PDF | |
8:34 AM - 8:39 AM | Failure Modes Of Chimney And Other Parallel Grafts And How They May Be Overcome |
Presenter(s):Claude Mialhe, MD | |
View Slides in PDF | |
8:40 AM - 8:45 AM | Inner Branched Endografts: A Better Solution For F/BEVAR Than Other Configurations For Treating Visceral Aortic Segment Lesions |
Presenter(s):Marcelo Ferreira, MD | |
View Slides in PDF | |
8:46 AM - 8:51 AM | Role Of Off-The-Shelf Fenestrated And Branched Grafts For Treating AAAs Involving The Visceral Segment Of The Aorta (Cook P-Branch And T-Branch) Devices: What Percent Of Patients Are Suitable |
Presenter(s):Mark A. Farber, MD | |
View Slides in PDF | |
8:52 AM - 8:57 AM | Patient Specific And Off-The-Shelf Devices Will Not Suffice For Many Patients With AAAs Involving The Visceral Aortic Segment: What Is The Solution |
Presenter(s):David J. Minion, MD | |
View Slides in PDF | |
8:58 AM - 9:05 AM | Panel Discussion |
9:05 AM - 9:20 AM | Break – Visit Exhibits And Pavilions (2nd and 3rd Floors) |
END OF SESSION 48 | |
previous | next |