Thursday
SESSION 58: NEW OR IMPROVED DEVICES FOR THORACIC AORTIC LESION REPAIRS WITH TEVAR, AND FOR THORACOABDOMINAL ANEURYSM (TAAA) REPAIRS (ALL TALKS ARE 4 ¾-MINUTES)
Location: Grand Ballroom West, 3rd Floor
Moderators:Giovanni B. Torsello, MD / James F. McKinsey, MD  
SESSION 58 SCHEDULE
DEVICES FOR TEVAR
10:15 AM - 10:20 AM Low Profile Devices For TEVAR: Disadvantages And Advantages Based On A 10-Year Experience
  Presenter(s):Giovanni B. Torsello, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
10:20 AM - 10:25 AM Mid-Term Results With The Cook ZENITH Alpha Thoracic Endograft For TEVAR In 500 Patients In A Real World Experience
  Presenter(s):Germano Melissano, MD / Roberto L.V. Chiesa, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
10:25 AM - 10:30 AM A Modified Candy Plug Technique For False Lumen Treatment After TEVAR For TBAD
  Presenter(s):Ali Azizzadeh, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
10:30 AM - 10:35 AM Fenestrated Endovascular Aortic Repair Plus Chimney Graft For TAAA Repairs: The FEVARCh Technique
  Presenter(s):Ross Milner, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
10:35 AM - 10:40 AM The Gore TAMBE Device: Lessons Learned To Facilitate Its Use For TAAA And Complex AAA Repairs
  Presenter(s):Bernardo C. Mendes, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
10:40 AM - 10:46 AM Panel Discussion
10:46 AM - 10:51 AM The Relay Pro (Terumo Aortic) Endograft For TEVAR And Its Advantages In Treating TBADs: Why Is It Better Than The Older Relay Plus Device
  Presenter(s):Steven D. Abramowitz, MD / Edward Y. Woo, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
10:51 AM - 10:56 AM Patient Specific Custom Designed Relay Pro Endografts (Terumo Aortic): How Do They Work And What Are Their Advantages In Various Circumstances
  Presenter(s):David M. Williams, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
10:56 AM - 11:01 AM

Power Point Presentation with Synched Audio
Relay Custom-Made Endografts (Terumo Aortic) For TEVAR: Why Do They Provide Better Wall Apposition For Sealing
  Presenter(s):Fadi Taher, MD / Afshin Assadian, MD  
Location: Grand Ballroom West, 3rd Floor
NEW OR IMPROVED ENDO DEVICES FOR TAAA REPAIRS
11:01 AM - 11:06 AM The Novel Artivion (Formerly CryoLife/Jotec) Off-The-Shelf (OTS) Inner Branched Device For TAAAs: Why Is It Better Than Outer Branched OTS Devices: Are There Limitations
  Presenter(s):Lee Bouwman, MD, PhD, MSc  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:06 AM - 11:11 AM Colt Concept And Its Evolution Towards The Inner Branch Endograft For Complex AAAs: Colt 2.0: How It Works And Early Outcomes
  Presenter(s):Piotr Szopinski, MD, PhD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:12 AM - 11:17 AM Panel Discussion
11:17 AM - 11:22 AM To Treat Complex TAAAs: Combination Of Relay (Terumo) TEVAR And Fenestrated And Branched EVAR Is Best: Technical Tips And Outcomes
  Presenter(s):Mo S. Hamady, MD, FRCR, EBIR, FSIR  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:22 AM - 11:27 AM Target Vessel Outcomes With The Cook t-Branch OTS Endograft For TAAA Repair At 2 Years From A Multicenter Registry – Which Stent-Graft Types Are Better For Which Vessels
  Presenter(s):Nikolaos Tsilimparis, MD; PhD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:27 AM - 11:32 AM Experience With The Cook t-Branch OTS Endograft Device For Juxta- And Pararenal AAAs: Advantages And Limitations
  Presenter(s):Matteo Orrico, MD / Nicola Mangialardi, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:32 AM - 11:37 AM Comparison Of 3 OTS Endografts For Urgent TAAA Repairs: TAMBE (Gore) Versus E-nside (Jotec) Versus t-Branch (Cook): Advantages And Disadvantages Of Each
  Presenter(s):Luca Bertoglio, MD / Roberto L.V. Chiesa, MD / Germano Melissano, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:37 AM - 11:42 AM Valiant Manifold OTS Endograft Device (Medtronic) For Repairing TAAAs: How Does It Work; Update On Clinical Experience And Future Prospects
  Presenter(s):Murray L. Shames, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:42 AM - 11:47 AM Innovative Treatment Of Thoracoabdominal And Pararenal Aortic Aneurysms Using Treovance Endografts (Terumo) And Parallel VBX Stent-Grafts (Gore)
  Presenter(s):James F. McKinsey, MD  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:48 AM - 11:53 AM Is There A Role For Hyperbaric Oxygen Therapy In Preventing Or Treating Spinal Cord Ischemia After TAAA Repair
  Presenter(s):Thomas F. Lindsay, MDCM, FRCS  
Location: Grand Ballroom West, 3rd Floor
  View Slides in PDF      
11:53 AM - 12:00 PM Panel Discussion
12:00 PM - 1:00 PM Lunch Break – Visit Exhibits And Pavilions (2nd and 3rd Floors)
END OF SESSION 58
previous next